PowerXchanger  |  SKU: EX-16

EX-16 | 1800W/16A | Step-Down Voltage & Frequency Converter – 220V/50Hz to 120V/60Hz

Regular price $1,595.00 USD


Model: EX-16

Input voltage: 200V/220V/230V/240V
Input frequency: 45Hz - 70Hz

Output voltage: 100V/110V/115V/120V (Selectable)
Output frequency: 60Hz or 50Hz (selectable)

Capacity: 1800W (16.8 Amp)
Maximum Output Current: 16.8 Amp

Your application power requirement should not exceed maximum output current.

View EX-16 Specifications

Available Capacities

in Economy (EX) Series

A table comparing the facets of 4 products
Facet
Model
Model
EX-8
EX-12
EX-16
EX-21
Price
Price
Regular price $1,050.00 USD
Regular price $1,195.00 USD
Regular price $1,595.00 USD
Regular price $1,895.00 USD
Current
Current
8.4 Amp
12.6 Amp
16.8 Amp
21.8 Amp
Capacity
Capacity
900W/1000VA
1350W/1500VA
1800W/2000VA
2340W/2600VA

EX-16

Outstanding performance & reliability, the unique benefits of the EX voltage & Frequency Converter
Overview
This series is a double conversion Power Converter which produces stable pure sine wave voltage and frequency output (O/P). With the Converter, you can protect your equipment from most of the power problems, including power sags, power surges, and line noise, etc. With the common neutral topology, the Converter provides internal connection from AC I/P neutral to AC O/P neutral; thus, it does not need to use an isolation transformer to provide 0 volt from AC I/P neutral to O/P neutral. This feature will reduce the interference to loads of communication or video system.
Features

With outstanding performance & reliability, the unique benefits of the Converter include the following:
  • Common Neutral, Double Conversion Topology
    (O/P Neutral to I/P Neutral is 0 volts normally)
  • Input Power Factor correction
  • Low Noise Smart Cooling Fan Design
  • High Efficiency, New Full-bridge Inverter Design
  • Full Function LCD Display
  • Automatic Restart of Loads After Overload Shutdown
  • AC Input Generator Compatible
Specification
Models EX-16
Output
Output capacity 1800W/2000VA
Output voltage 100V/110V/115V/120V (Selectable)
Maximum output current 16.8 Amp
Output peak current 250ms 52 Amp
Maximum continuous load 1800W
Maximum peak load 2400W
Voltage regulation ±2% of selected output voltage
Output frequency 60Hz or 50Hz (selectable)
Output frequency synchronization 60±0.01Hz or 50±0.01Hz (independent of input frequency)
Crest factor 3:1
Voltage waveform Sine Wave
Total harmonic distortion resistive load <2%
Total harmonic distortion reactive load <3%
Standby power 27W
Output emi filter N/A
Output rfi filter 30Mhz - 1000Mhz
Clamp level 200V Peak
Efficiency input to output >89%
Output Connection From Mains
Ground Input and Output Ground are Connected
Neutral Input and Output Neutral Connected (after EMC inductor ) Isolation Transformer is not required
Input
Nominal input voltage 200V/220V/230V/240V
Input voltage range 180Vac ~ 285Vac
Input current 12 Amp
Input frequency range 45Hz - 70Hz
Input neutral auto detect and correct No
Wall outlet type required Includes 4 Input Plug Types
Phase Single
Noise filtering Full-Time EMI/RFI Filtering
Input emi filter 150Khz -30Mhz (class A)
Input rfi filter 30Mhz - 1000Mhz (class A)
Overcurrent protection input By Re-Settable; Overcurrent Protector
Power factor ≧ 0.98
Switch on surge in rush current <100A, 3mS
Voltage interruption ride through 10mS
Protection
Overcurrent protection output Overload Alarm Level: 100% ~ 129% (alarm after 1 minute delay, shutdown after 1 minute alarm); Overload Shutdown Level: 130% (shutdown after 2 second delay)
Short circuit protection Pulsating Type, 52A Peak; Auto-Restart time: 30 seconds
Over temperature protection When the temperature inside is over 76℃, the LCD will show the Over-Temperature Symbol. If the temperature continues rising to 85℃, the buzzer alert for high temperature is activated and the CPU will shut down the output voltage. The CPU will resume output voltage automatically once the temperature drops to 75℃ or lower.
Indicators and Alarms
Lcd display Displays Input Voltage, Output Voltage, Output Frequency, Temperature, Load Level. Selectable Output Voltage and Output Frequency
Indicator load level LCD Displays Current Usage Level of Total Available Capacity
Indicator overload LCD Shows Overload Symbol
Indicator over temperature LCD Shows Over-Temperature Symbol
Audible alarms Overload Alarm, Short-Circuit Alarm, Over-Temperature Alarm
Audible alarm overload Continuous Alarm
Audible alarm short circuit Every other 2 seconds, 32 beeps in 2 seconds
Audible alarm over temperature Every other 2 seconds, 32 beeps in 2 seconds
Environmental and Safety
Sealed solid state electronics No
Operating temperature Up to 1500 meters: 0℃ to 40℃ (32℉ to 104℉)
Transit storage temp -15℃ to 55℃ (5℉ to 131℉)
Relative humidity 5 – 95% Non-Condensing
Operating altitude 0 ~ 3000 Meters
Moisture sensitivity Internal Fan
Audible noise ≦45 dBA (at 1 meter from surface of unit)
Safety markings CE
Cooling
Cooling method Forced Air Cooling by Internal Fan
Natural ventilation cooling No
Internal fans Internal fan will run at low speed continuously when the temperature inside is low. Fan speed increases as temperature rises. When internal temperature is over 60° C, the internal fan runs at full speed
External emergency cooling fan N/A
Physical
Product dimensions
(L x W x H)
20.08 in x 7.78 in x 7.08 in / 51 cm x 20 cm x 18 cm
Product weight 17.64 lb / 8 kg
Carton dimensions
(L x W x H)
28 in x 15 in x 17 in / 72 cm x 38 cm x 43 cm
Shipping weight 30 lb / 13.6 kg
Warranty, Quality Control, and International Approvals
Warranty 2 Years, Full Replacement
Quality control standard ISO9001
UL-ULus Not Applicable
UL 1012 Not Applicable
UL-cUL Not Applicable
DEMKO-CB Not Applicable
TUV/SUD-CB Not Applicable
FCC Part 15 Not Applicable
EMC Not Applicable
Other
Standard accessories Input Power Cords, Type F, Type G, Type I, Type M.
Wall mountable No
Appliance mountable No
Compatibility
Output compatibility with ups Yes
Ac input generator compatible Yes

General

Can I run a 60Hz motor on 50Hz power supply?

Running a 60 Hz motor on a 50 Hz supply will make it run
about 20% slower. This can cause extra heat, vibration, and reduced torque
depending on the design. Some motors are built for both 50/60 Hz and will work
safely, while others may wear out quickly or fail.

To ensure proper performance and protect your equipment, we
recommend using a PowerXchanger frequency converter.

How do I know if I need a frequency converter or a voltage transformer?

A voltage transformer only changes the voltage, while a frequency converter changes both voltage and frequency.

If your equipment label shows it supports both 50/60 Hz, you usually only need a transformer to match the voltage. If it specifies a single frequency (50 Hz or 60 Hz only), then you will need a frequency converter to run it properly.

Always check the rating plate on your device to determine which solution is required.

Returns and Refunds

How do I return a product?

Items must be returned within 30 days after receiving your order. Items must be returned in the same condition in which they were received, be unworn/unused, have any tags still attached, and include all the original packaging.

How long will it take to receive my refund?

Refunds are processed within 7 days from when we receive the item(s).

Shipping

How long will it take to receive my order?

Standard shipping normally takes 3-5 days. Next day shipping is available on all domestic orders (for an additional charge). International shipping times depend on the products and destination (estimated at checkout).

What countries do you ship to?

We currently ship to the United States, Canada, Australia and the UK. To enquire about shipping to a different destination, please contact us.

Technology

What is the difference between a voltage transformer and a frequency converter?

Voltage transformers adjust the voltage level (e.g., from 230 V down to 110 V), protecting your devices from overvoltage
damage.

Frequency converters ensure that the electrical frequency (50 Hz vs. 60 Hz) matches what your device was built for.

Why does the frequency matter?

Because so many devices, from washing machines and CPAP
Machines to audio equipment, kitchen appliances, and tools all rely on precise
timing or motor speed governed by the mains frequency. Run a 60 Hz-designed
motor or compressor at 50 Hz, and it will spin slower, draw more current,
overheat, or fail altogether.