PowerXchanger  |  SKU: 12060X-15-WW

X-15 | 1800W/15A | Step-Down Voltage & Frequency Converter – 220V/50Hz to 120V/60Hz

Regular price $2,350.00 USD


Model: X-15

Input voltage: 200V/220V/230V/240V
Input frequency: 46Hz - 65Hz

Output voltage: 120V
Output frequency: 60Hz

Capacity: 1800W (15 Amp)
Maximum Output Current: 15 Amp

The X-15 is the world’s most powerful Voltage and Frequency converter available for personal use.

While being small and portable, it regenerates 15 Amp and 120V~60Hz of power that exceed in quality and regulation of a dual socket home outlet.

View X-15 Specifications

Available Capacities

in Deluxe (X) Series & Slimline (XS) Series

A table comparing the facets of 4 products
Facet
Model
Model
XS-05GA
X-5
X-10
X-15
Current
Current
5 Amp
5 Amp
10 Amp
15 Amp
Capacity
Capacity
600W/600VA
600W/600VA
1200W/1200VA
1800W/1800VA
Price
Price
Regular price $1,450.00 USD
Regular price $1,250.00 USD
Regular price $1,850.00 USD
Regular price $2,350.00 USD

X-15

The most powerful Voltage & Frequency converter
X-15 | 1800W/15A | Step-Down Voltage & Frequency Converter – 220V/50Hz to 120V/60Hz

What's in the box?

  1. X-15
  2. Wall mount
  3. Extension outlet
  4. Input Power Cords, Type F, Type G, Type I, Type M.

What's in X-15 box?

Overview
The X-15 is the world’s most powerful, yet portable Voltage and Frequency converter available for personal use while matching the power of a dual socket home outlet.

X-15 is a full-featured sine wave output regenerator that produces new, clean, and constant AC power; eliminating line noise and ensuring optimum performance. It is capable of providing 120V~60Hz electricity for running household appliances such as refrigerators, gas stoves, washers, gas dryers, microwaves, household power tools, small appliances and even commercial vacuum cleaners.

With all its sophistication, the X-15 is the same size and weight of a typical amplifier or game console.

When location and space is an issue, the detachable legs, included wall mounting kit and Xchange® Extension Outlet allow this unit to be placed virtually anywhere – up to 6ft away from the appliance it’s meant to power!

Power
With sophisticated electronics including power factor correction, as well as input and output EMI and RFI filters, it produces continuous power at over 92% (typical) efficiency and with output Harmonic distortion below <3%. High levels of regulation ensure 120V~60Hz output with fluctuations below ± 2%, making it the ideal conversion device for taking high-end audio and home theater equipment overseas.

Power for High Performance Audio
To the audiophile, the X-15 functions as a Regenerator with Power Factor Correction (PFC). It is a premiere choice for powering audio equipment to satisfy the most demanding audiophiles. With its clean sinewave output (typically < 1%THD) and with virtually no change in amplitude due to input voltage fluctuations and output load transients, audio equipment will always function with optimal performance. Because the output of the X-15 regulates so well, another advantage to the audiophile is that other equipment powered by the X-15, such as HDTVs and DVRs, will not introduce noise or distortion to the audio output via the common power connection.

Additionally excellent EMI filtering on the input and output of the X-15 prevents RFI noise from being injected into the audio output.

Another important feature for audiophiles is the high output surge current capacity (150 Amps) of the X-15. This capability to source high surge currents with minimal distortion of the output voltage results with crisp high volume audio transients.

Frequently overlooked is the importance of PFC for noise free operation of audio equipment. Because PFC eliminates voltage and current distortions on the input power leads to the X-15, this potential source of audio noise is virtually non-existent.

Reliability
The X-15 has sealed solid-state electronics that protect against humidity and dust, ensuring reliability and a long product life. An External Fan automatically cools the sealed electronics whenever the load exceeds 15 Amps or when environmental factors exceed operating temperature.

Safety
Not only will electrical equipment perform better, but the X-15 also acts as an advanced voltage regulator, which fully protects equipment against voltage irregularities, such as under INPUT voltage as low as 180Vac and over voltage as high as 265Vac and provides an appliance with inrush surge protection of up to 150 Amps.

Audible alarms notify overload, short circuit and temperature while in addition; an external LED provides visual notification of overload and temperature status. A built-in LCD Display provides on-demand operational data such as connected load levels, remaining available capacity, input voltage, output converted voltage, output converted frequency, and internal device temperature.

The X-15 not only meets the stringent standards of the UL and FCC in the USA, but also meets International Safety Standards.

Features
  • Frequency Converter
  • Voltage Converter
  • Sophisticated Voltage Regulator
  • Surge Protection
  • Short Circuit Protection
  • Over-Current Protection
  • Power Factor Correction (PFC)
  • Thermal Protection
  • Lightweight
  • High Efficiency
  • Input EMI and RFI Filters
  • Output EMI and RFI Filters
  • Low Harmonic Distortion
  • Sealed, Solid State Electronics
  • External Cooling Fan
  • Continuous Power
  • Audible Alarms
  • Led Status Indicator
  • LCD Display
  • International Approvals
  • Wall Mount Option with Included Kit
  • Desktop unit with Removable Legs
  • Dual Socket
  • Includes Xchange® Extension Outlet
Some applications may require isolation from main power grid. We can offer PowerXchanger designed and manufactured Isolation Transformer XTI-ISO2K.

If your application is in conjunction with the purchase of a PowerXchanger product we can offer a reduced packaged price.

Please contact us via e-mail contact@PowerXchanger.com for technical support and pricing.
Specification
Models X-15
Output
Output capacity 1800W/1800VA
Output voltage 120V
Maximum output current 15 Amp
Output peak current 250ms 45A
Maximum continuous load 1800W
Maximum peak load 3000W
Voltage regulation ± 2% of output voltage
Output frequency 60Hz
Output frequency synchronization Auto-Synchronized to Main (Input Frequency of 50Hz is Digitally Converted to 60Hz Output)
Crest factor 3:1
Voltage waveform Sine Wave
Total harmonic distortion resistive load <2%
Total harmonic distortion reactive load <3%
Standby power 19W
Output emi filter 150Khz - 30Mhz
Output rfi filter 30Mhz - 1000Mhz
Clamp level 190V
Efficiency input to output 92% (typical)
Output Connection From Mains
Ground Input and Output Ground are Connected
Neutral An isolation transformer is required at the ac input for connecting Ground with the output Neutral
Input
Nominal input voltage 200V/220V/230V/240V
Input voltage range 180Vac ~ 265Vac
Input current 12 Amp
Input frequency range 46Hz - 65Hz
Input neutral auto detect and correct No
Wall outlet type required Includes 4 Input Plug Types
Phase Single
Noise filtering Full-Time EMI/RFI Filtering
Input emi filter 150Khz - 30Mhz
Input rfi filter 30Mhz - 1000Mhz
Overcurrent protection input By Re-Settable; Overcurrent Protector
Power factor ≧ 0.95
Switch on surge in rush current <150A, 2ms
Voltage interruption ride through 20mS
Protection
Overcurrent protection output Overload Alarm Level: 120% ~ 149% (alarm after 1 minute delay, shutdown after 1 minute alarm); Overload Shutdown Level: 150% (shutdown after 2 second delay)
Short circuit protection Pulsating Type, 40A Peak; Auto-Restart time: 30 seconds
Over temperature protection When the temperature inside rises above 76℃, the LED X will blink every 2 seconds and the buzzer alarm is activated. LCD shows Over-Temperature Symbol. If the temperature continues rising to 80℃, the CPU will shut down the output voltage after a 1 minute delay, and turn back on automatically once the temperature drops to 78℃ or lower.
Indicators and Alarms
Lcd display Display Input Voltage, Output Voltage, Output Frequency, Temperature, Load Level
Indicator load level LCD Displays Current Usage Level of Total Available Capacity
Indicator overload LED X blinks every 4 seconds; LCD Shows Overload Symbol
Indicator over temperature LED X blinks every 2 seconds; LCD Shows Over-Temperature Symbol
Audible alarms Overload Alarm, Short-Circuit Alarm, Over-Temperature Alarm
Audible alarm overload Continuous Alarm
Audible alarm short circuit 1 beep every 2 seconds
Audible alarm over temperature Every other 2 seconds, 32 beeps in 2 seconds
Environmental and Safety
Sealed solid state electronics Yes
Operating temperature Up to 2000 Meters: 0° to 45°C (32°F to 113°F)
Transit storage temp -15°C to 60°C (5°F to 140°F)
Relative humidity 5 – 95% Non-Condensing
Operating altitude 0 ~ 3000 Meters
Moisture sensitivity Sealed Electronics
Audible noise No Noise, Silent Operation
Safety markings UL, UC, CB, CE, Demko, TUV, FCC
Cooling
Cooling method Natural Ventilation with No Internal Fans
Natural ventilation cooling Yes
Internal fans No
External emergency cooling fan Auto on/off, smart external fan is controlled by heat sink temperature & load level.
Physical
Product dimensions
(L x W x H)
16.34 in x 10.83 in x 6.5 in / 41.5 cm x 27.5 cm x 16.5 cm
Product weight 27.21 lb / 12.34 kg
Carton dimensions
(L x W x H)
22.83 in x 13.78 in x 22.83 in / 58 cm x 35 cm x 58 cm
Shipping weight 44.8 lb / 20.32 kg
Warranty, Quality Control, and International Approvals
Warranty 2 Years, Full Replacement
Quality control standard ISO9001
UL-ULus UL-ULus (CCN: QQFU/7) Power Units Other Than Class 2,
UL 1012 UL 1012, Seven Edition, October 14, 2008
UL-cUL UL-cUL: CAN/CSA-C22.2 No. 107.1-01, September, 2001
DEMKO-CB DEMKO-CB IEC60950-1:2005+A1:2009+A2:2013 (Ed. 2.2)
TUV/SUD-CB TUV/SUD-CB IEC 60335-1:2010+A1:2013 (Ed. 5.1)
FCC Part 15 FCC Part 15: subpart B
EMC EMC 2004/108/EC
Other
Standard accessories Input Power Cords, Type F, Type G, Type I, Type M. Xchange Outlet [White] Wall Mount Plate
Wall mountable Yes
Appliance mountable No
Compatibility
Output compatibility with ups Not Suggested
Ac input generator compatible Yes

General

Can I run a 60Hz motor on 50Hz power supply?

Running a 60 Hz motor on a 50 Hz supply will make it run
about 20% slower. This can cause extra heat, vibration, and reduced torque
depending on the design. Some motors are built for both 50/60 Hz and will work
safely, while others may wear out quickly or fail.

To ensure proper performance and protect your equipment, we
recommend using a PowerXchanger frequency converter.

How do I know if I need a frequency converter or a voltage transformer?

A voltage transformer only changes the voltage, while a frequency converter changes both voltage and frequency.

If your equipment label shows it supports both 50/60 Hz, you usually only need a transformer to match the voltage. If it specifies a single frequency (50 Hz or 60 Hz only), then you will need a frequency converter to run it properly.

Always check the rating plate on your device to determine which solution is required.

Returns and Refunds

How do I return a product?

Items must be returned within 30 days after receiving your order. Items must be returned in the same condition in which they were received, be unworn/unused, have any tags still attached, and include all the original packaging.

How long will it take to receive my refund?

Refunds are processed within 7 days from when we receive the item(s).

Shipping

How long will it take to receive my order?

Standard shipping normally takes 3-5 days. Next day shipping is available on all domestic orders (for an additional charge). International shipping times depend on the products and destination (estimated at checkout).

What countries do you ship to?

We currently ship to the United States, Canada, Australia and the UK. To enquire about shipping to a different destination, please contact us.

Technology

What is the difference between a voltage transformer and a frequency converter?

Voltage transformers adjust the voltage level (e.g., from 230 V down to 110 V), protecting your devices from overvoltage
damage.

Frequency converters ensure that the electrical frequency (50 Hz vs. 60 Hz) matches what your device was built for.

Why does the frequency matter?

Because so many devices, from washing machines and CPAP
Machines to audio equipment, kitchen appliances, and tools all rely on precise
timing or motor speed governed by the mains frequency. Run a 60 Hz-designed
motor or compressor at 50 Hz, and it will spin slower, draw more current,
overheat, or fail altogether.