XS-05 GA | 600W/5A | Step-Down Voltage & Frequency Converter – 220V/50Hz to 120V/60Hz
XS-05 GA | 600W/5A | Step-Down Voltage & Frequency Converter – 220V/50Hz to 120V/60Hz is backordered and will ship as soon as it is back in stock.
Model: XS-05GA
Input voltage: 200V/220V/230V/240V
Input frequency: 46Hz - 65Hz
Output voltage: 120V
Output frequency: 60Hz
Capacity: 600W (5 Amp)
Maximum Output Current: 5 Amp
Available Capacities
in Slimline (XS) Series & Deluxe (X) Series
XS-05GA
The worlds slimmest and lightest wall-mounted Step Down Transformer
PowerXchanger Slimline Series built-in 3-PIN locking connector assures secure and spark less connection
For a secured connection between the electrical appliance and your brand new PowerXchanger Slimline Series (XS-05 GA or XRT-750), make sure to push the plug all the way in until the clip locked in with the 3-pin Locking Connector(s).Please refer to the video below:
The XS-05 uses the overseas utilities electrical power to regenerate a new power that not only has the correct voltage and frequency, but through various filters and levels of control, acts as a voltage regulator that eliminates surges and transients. A power factor corrected input (PFC) provides harmonic filtering on the input by removing voltage and current distortions that may be caused by the appliance. The XS-05 provides the appliance with a high quality, constant, and noise free electrical output of 120v~60 Hz – anywhere in the world.
An appliance intended for the USA is designed, manufactured and tested to operate in a 120v~60 Hz environment. As appliances have evolved in electrical sophistication and government efficiency standards have continuously become more stringent, engineers are forced to design each individual component, and the unit itself, to operate in the substantially more efficient 60 Hz.
Installing a step-down transformer to power a 120v~60 Hz designed appliance from a 220v~50 Hz grid will cause the appliance to operate at 50 Hz. At best – it functions but not properly. But most likely, the appliance will have a shortened product life, failed components and unforeseen damage resulting in catastrophic failure.
In other words, the XS-05 does not power the appliance like an installed transformer. It is an adapter that converts 50 Hz utility power, providing an appliance with the correct voltage and frequency of 120v~60 Hz that it was designed and tested for.
The XS-05 is a rugged full-featured device. Its specialized connecters provide for secure and safe installation. Its slim, lightweight design allows it to be mounted onto an appliance, or nearby via the included mounting plate.
Power
XS-05 is a full-featured sine wave output regenerator that produces new, clean, and constant AC power; eliminating line noise and ensuring optimum performance. It is capable of providing 120v~60 Hz electricity for running a single household appliance (up to 600W).
Through sophisticated electronics, as well as input and output EMI and RFI filters, it produces continuous power at over 92% efficiency and with output Harmonic distortion below 3%. High levels of regulation ensure 120v~60 Hz output with fluctuations below ± 2% (typical less than 1%).
Power for High Performance Audio
To the audiophile, the XS-05 functions as a Regenerator with Power Factor Correction (PFC). It is a premiere choice for powering audio equipment to satisfy the most demanding audiophiles. With its clean sinewave output (typically < 1%THD) and with virtually no change in amplitude due to input voltage fluctuations and output load transients, audio equipment will always function with optimal performance. Because the output of the XS-05 regulates so well, another advantage to the audiophile is that other equipment powered by the XS-05, such as HDTVs and DVRs, will not introduce noise or distortion to the audio output via the common power connection.
Additionally excellent EMI filtering on the input and output of the XS-05 prevents RFI noise from being injected into the audio output.
Another important feature for audiophiles is the high output surge current capacity (150 Amps) of the XS-05. This capability to source high surge currents with minimal distortion of the output voltage results with crisp high volume audio transients.
Frequently overlooked is the importance of PFC for noise free operation of audio equipment. Because PFC eliminates voltage and current distortions on the input power leads to the XS-05, this potential source of audio noise is virtually non-existent.
Reliability
The XS-05 has sealed, solid-state electronics that protect against humidity and dust, ensuring reliability and a long product life.
Safety
Not only will electrical equipment perform better, but the XS-05 also acts as an advanced voltage regulator, which fully protects equipment against voltage irregularities such as under INPUT voltage as low as 180Vac and over voltage as high as 265Vac and provides an appliance with inrush surge protection of up to 150 Amps.
Audible alarms notify overload, short circuit and temperature.
The XS-05 meets International Standards. Even though this device would probably not be used in the USA, it also comes with UL and FCC approvals, giving the manufacturer/installer and the end user the confidence that their appliances, which meet these safety standards, are connecting to a device that is also meeting these safety standards.
- Frequency Converter
- Voltage Converter
- Sophisticated Voltage Regulator
- Surge Protection
- Short Circuit Protection
- Over-Current Protection
- Power Factor Correction (PFC)
- Thermal Protection
- Lightweight
- High Efficiency
- Input EMI and RFI Filters
- Output EMI and RFI Filters
- Low Harmonic Distortion
- Sealed, Solid State Electronics
- Continuous Power
- Audible Alarms
- International Approvals
- Wall Mounting Kit
If your application is in conjunction with the purchase of a PowerXchanger product we can offer a reduced packaged price.
Please contact us via e-mail contact@PowerXchanger.com for technical support and pricing.
| Specification | |
| Models | XS-05GA |
| Output | |
| Output capacity | 600W/600VA |
| Output voltage | 120V |
| Maximum output current | 5 Amp |
| Output peak current 250ms | 40A |
| Maximum continuous load | 600W |
| Maximum peak load | 1000W |
| Voltage regulation | ± 2% of output voltage |
| Output frequency | 60Hz |
| Output frequency synchronization | Auto-Synchronized to Main (Input Frequency of 50Hz is Digitally Converted to 60Hz Output) |
| Crest factor | 8:1 |
| Voltage waveform | Sine Wave |
| Total harmonic distortion resistive load | <2% |
| Total harmonic distortion reactive load | <3% |
| Standby power | 17W |
| Output emi filter | 150Khz - 30Mhz |
| Output rfi filter | 30Mhz - 1000Mhz |
| Clamp level | 190V |
| Efficiency input to output | 92% (typical) |
| Output Connection From Mains | |
| Ground | Input and Output Ground are Connected |
| Neutral | An isolation transformer is required at the ac input for connecting Ground with the output Neutral |
| Input | |
| Nominal input voltage | 200V/220V/230V/240V |
| Input voltage range | 180Vac ~ 265Vac |
| Input current | 4 Amp |
| Input frequency range | 46Hz - 65Hz |
| Input neutral auto detect and correct | No |
| Wall outlet type required | Includes 4 Input Plug Types |
| Phase | Single |
| Noise filtering | Full-Time EMI/RFI Filtering |
| Input emi filter | 150Khz - 30Mhz |
| Input rfi filter | 30Mhz - 1000Mhz |
| Overcurrent protection input | By Re-Settable; Overcurrent Protector |
| Power factor | ≧ 0.95 |
| Switch on surge in rush current | <150A, 2ms |
| Voltage interruption ride through | 30mS |
| Protection | |
| Overcurrent protection output | Overload Alarm Level: 120% ~ 149% (alarm after 1 minute delay, shutdown after 1 minute alarm); Overload Shutdown Level: 150% (shutdown after 2 second delay) |
| Short circuit protection | Pulsating Type, 40A Peak; Auto-Restart time: 30 seconds |
| Over temperature protection | When the temperature inside rises above 76℃, the LED X will blink every 2 seconds and the buzzer alarm is activated. If the temperature continues rising to 80℃, the CPU will shut down the output voltage after a 1 minute delay, and turn back on automatically once the temperature drops to 78℃ or lower. |
| Indicators and Alarms | |
| Lcd display | No |
| Indicator load level | N/A |
| Indicator overload | LED Indicator blinks every 4 seconds |
| Indicator over temperature | LED Indicator blinks every 2 seconds |
| Audible alarms | Overload Alarm, Short-Circuit Alarm, Over-Temperature Alarm |
| Audible alarm overload | Continuous Alarm |
| Audible alarm short circuit | 1 beep every 2 seconds |
| Audible alarm over temperature | Every other 2 seconds, 32 beeps in 2 seconds |
| Environmental and Safety | |
| Sealed solid state electronics | Yes |
| Operating temperature | Up to 2000 Meters: 0° to 45°C (32°F to 113°F) |
| Transit storage temp | -15°C to 60°C (5°F to 140°F) |
| Relative humidity | 5 – 95% Non-Condensing |
| Operating altitude | 0 ~ 3000 Meters |
| Moisture sensitivity | Sealed Electronics |
| Audible noise | No Noise, Silent Operation |
| Safety markings | UL,UC,CB,CE,Demko,TUV,FCC UL,UC,CB,CE,Demko,TUV,FCC UL,UC,CB,CE,Demko,TUV,FCC UL,UC,CB,CE,Demko,TUV,FCC |
| Cooling | |
| Cooling method | Natural Ventilation with No Internal Fans |
| Natural ventilation cooling | Yes |
| Internal fans | No |
| External emergency cooling fan | N/A |
| Physical | |
| Product dimensions (L x W x H) |
13.78 in x 10.63 in x 2.36 in / 35 cm x 27 cm x 6 cm |
| Product weight | 10.67 lb / 4.84 kg |
| Carton dimensions (L x W x H) |
20.08 in x 18.5 in x 7.78 in / 51 cm x 47 cm x 20 cm |
| Shipping weight | 21.03 lb / 9.54 kg |
| Warranty, Quality Control, and International Approvals | |
| Warranty | 2 Years, Full Replacement |
| Quality control standard | ISO9001 |
| UL-ULus | UL-ULus (CCN: QQFU/7) Power Units Other Than Class 2, |
| UL 1012 | UL 1012, Seven Edition, October 14, 2008 |
| UL-cUL | UL-cUL: CAN/CSA-C22.2 No. 107.1-01, September, 2001 |
| DEMKO-CB | DEMKO-CB IEC60950-1:2005+A1:2009+A2:2013 (Ed. 2.2) |
| TUV/SUD-CB | TUV/SUD-CB IEC 60335-1:2010+A1:2013 (Ed. 5.1) |
| FCC Part 15 | FCC Part 15: subpart B |
| EMC | EMC 2004/108/EC |
| Other | |
| Standard accessories | Input Power Cords, Type F, Type G, Type I, Type M. Wall/Appliance Mount |
| Wall mountable | Yes |
| Appliance mountable | Yes |
| Compatibility | |
| Output compatibility with ups | Not Suggested |
| Ac input generator compatible | Yes |