Voltage Regulation: 220V/50Hz to 120V/60Hz Converter Test
Watch the PowerXchanger X-10 hold steady 120V/60Hz output as input swings from 120V to 250V. See why our active voltage regulation beats a transformer overseas.
X-15 | 1800W/15A | Step-Down Voltage & Frequency Converter – 220V/50Hz to 120V/60Hz is backordered and will ship as soon as it is back in stock.
Model: X-15
Input voltage: 200V/220V/230V/240V
Input frequency: 46Hz - 65Hz
Output voltage: 120V
Output frequency: 60Hz
Capacity: 1800W (15 Amp)
Maximum Output Current: 15 Amp
X-15 | 1800W/15A | Step-Down Voltage & Frequency Converter – 220V/50Hz to 120V/60Hz is backordered and will ship as soon as it is back in stock.
in Deluxe (X) Series & Slimline (XS) Series

The PowerXchanger Deluxe Series are the only frequency converters with both UL and CE certification.
EMI/RFI filters at both input and output ensures you get superior, clean, and well regulated 120V/60Hz power, even in the harshest international power environments

| Specification | |
| Models | X-15 |
| Output | |
| Output capacity | 1800W/1800VA |
| Output voltage | 120V |
| Maximum output current | 15 Amp |
| Output peak current 250ms | 45A |
| Maximum continuous load | 1800W |
| Maximum peak load | 3000W |
| Voltage regulation | ± 2% of output voltage |
| Output frequency | 60Hz |
| Output frequency synchronization | Auto-Synchronized to Main (Input Frequency of 50Hz is Digitally Converted to 60Hz Output) |
| Crest factor | 3:1 |
| Voltage waveform | Sine Wave |
| Total harmonic distortion resistive load | <2% |
| Total harmonic distortion reactive load | <3% |
| Standby power | 19W |
| Output emi filter | 150Khz - 30Mhz |
| Output rfi filter | 30Mhz - 1000Mhz |
| Clamp level | 190V |
| Efficiency input to output | 92% (typical) |
| Output Connection From Mains | |
| Ground | Input and Output Ground are Connected |
| Neutral | An isolation transformer is required at the ac input for connecting Ground with the output Neutral |
| Input | |
| Nominal input voltage | 200V/220V/230V/240V |
| Input voltage range | 180Vac ~ 265Vac |
| Input current | 12 Amp |
| Input frequency range | 46Hz - 65Hz |
| Input neutral auto detect and correct | No |
| Wall outlet type required | Includes 4 Input Plug Types |
| Phase | Single |
| Noise filtering | Full-Time EMI/RFI Filtering |
| Input emi filter | 150Khz - 30Mhz |
| Input rfi filter | 30Mhz - 1000Mhz |
| Overcurrent protection input | By Re-Settable; Overcurrent Protector |
| Power factor | ≧ 0.95 |
| Switch on surge in rush current | <150A, 2ms |
| Voltage interruption ride through | 20mS |
| Protection | |
| Overcurrent protection output | Overload Alarm Level: 120% ~ 149% (alarm after 1 minute delay, shutdown after 1 minute alarm); Overload Shutdown Level: 150% (shutdown after 2 second delay) |
| Short circuit protection | Pulsating Type, 40A Peak; Auto-Restart time: 30 seconds |
| Over temperature protection | When the temperature inside rises above 76℃, the LED X will blink every 2 seconds and the buzzer alarm is activated. LCD shows Over-Temperature Symbol. If the temperature continues rising to 80℃, the CPU will shut down the output voltage after a 1 minute delay, and turn back on automatically once the temperature drops to 78℃ or lower. |
| Indicators and Alarms | |
| Lcd display | Display Input Voltage, Output Voltage, Output Frequency, Temperature, Load Level |
| Indicator load level | LCD Displays Current Usage Level of Total Available Capacity |
| Indicator overload | LED X blinks every 4 seconds; LCD Shows Overload Symbol |
| Indicator over temperature | LED X blinks every 2 seconds; LCD Shows Over-Temperature Symbol |
| Audible alarms | Overload Alarm, Short-Circuit Alarm, Over-Temperature Alarm |
| Audible alarm overload | Continuous Alarm |
| Audible alarm short circuit | 1 beep every 2 seconds |
| Audible alarm over temperature | Every other 2 seconds, 32 beeps in 2 seconds |
| Environmental and Safety | |
| Sealed solid state electronics | Yes |
| Operating temperature | Up to 2000 Meters: 0° to 45°C (32°F to 113°F) |
| Transit storage temp | -15°C to 60°C (5°F to 140°F) |
| Relative humidity | 5 – 95% Non-Condensing |
| Operating altitude | 0 ~ 3000 Meters |
| Moisture sensitivity | Sealed Electronics |
| Audible noise | No Noise, Silent Operation |
| Safety markings | UL, UC, CB, CE, Demko, TUV, FCC |
| Cooling | |
| Cooling method | Natural Ventilation with No Internal Fans |
| Natural ventilation cooling | Yes |
| Internal fans | No |
| External emergency cooling fan | Auto on/off, smart external fan is controlled by heat sink temperature & load level. |
| Physical | |
| Product dimensions (L x W x H) |
16.34 in x 10.83 in x 6.5 in / 41.5 cm x 27.5 cm x 16.5 cm |
| Product weight | 27.21 lb / 12.34 kg |
| Carton dimensions (L x W x H) |
22.83 in x 13.78 in x 22.83 in / 58 cm x 35 cm x 58 cm |
| Shipping weight | 44.8 lb / 20.32 kg |
| Warranty, Quality Control, and International Approvals | |
| Warranty | 2 Years, Full Replacement |
| Quality control standard | ISO9001 |
| UL-ULus | UL-ULus (CCN: QQFU/7) Power Units Other Than Class 2, |
| UL 1012 | UL 1012, Seven Edition, October 14, 2008 |
| UL-cUL | UL-cUL: CAN/CSA-C22.2 No. 107.1-01, September, 2001 |
| DEMKO-CB | DEMKO-CB IEC60950-1:2005+A1:2009+A2:2013 (Ed. 2.2) |
| TUV/SUD-CB | TUV/SUD-CB IEC 60335-1:2010+A1:2013 (Ed. 5.1) |
| FCC Part 15 | FCC Part 15: subpart B |
| EMC | EMC 2004/108/EC |
| Other | |
| Standard accessories | Input Power Cords, Type F, Type G, Type I, Type M. Xchange Outlet [White] Wall Mount Plate |
| Wall mountable | Yes |
| Appliance mountable | No |
| Compatibility | |
| Output compatibility with ups | Not Suggested |
| Ac input generator compatible | Yes |